CCM-0006
Condition
Diagnostic trouble code (DTC) CCM-0006 is stored if the control module registers that the signal from the evaporator temperature sensor is below 2% of the supply voltage (approximately 5 V).
Condition
- The control module adopts a substitute value corresponding to approximately 0 degrees C.
Possible source
- Short-circuit to ground in the signal cable.
- Defective evaporator temperature sensor.
Fault symptom[s]
- No cooling from the air conditioning (A/C) system.
- The air conditioning (A/C) compressor does not start, or runs sporadically.
- Irregular cooling from the air conditioning (A/C) system.