AEM-6C52
Condition
Diagnostic trouble code (DTC) AEM-6C52 is stored if the control module registers that the signal is too low or there is an open-circuit in the signal cable for alarm output P1.
The diagnostic trouble code (DTC) can be diagnosed when the ignition is on and alarm output P1 is not activated.
Substitute value
- None.
Possible source
- Short-circuit to ground in the signal cable for alarm output P1.
- Open-circuit in the signal cable for alarm output P1.
- Defective alarm.
Fault symptom[s]
- The alarm does not function at all.