Circuit Error
Circuit error
Checking the wiring
- Ignition off, wait for 10 seconds.
- Disconnect the connector from the left-hand inflatable curtain.
- Disconnect the connector for Supplemental restraint system module (SRS).
Warning! Under no circumstances use an ohmmeter or other live measuring instrument to take readings on a disconnected, non-deployed, pyrotechnical inflatable curtain. This could deploy the inflatable curtain!
Check connectors for damage to pins and connections.
Check the connectors. Check for loose connections. Check for contact resistance. Check for oxidation.
Also check other connectors and terminals that connect the wiring between the Supplemental restraint system module (SRS) and the inflatable curtain.
Check the cable. Check for loose connections. Check for an open-circuit. Check for a short-circuit to ground. Check for a short-circuit to supply voltage.
Take readings between:
- Supplemental restraint system module (SRS) terminal #21A/21(21) and connector to inflatable curtain, left, terminal #1.
- Supplemental restraint system module (SRS) terminal #22A/22(22) and connector to inflatable curtain, left, front, terminal #3.
Remedy as necessary.
Other information
- Connecting the breakout box Connecting the Breakout Box, Supplemental Restraint System Module (SRS)
- Signal specification Signal Specification, Supplemental Restraint System Module (SRS)
- For further information, see the wiring diagram.
- IC (inflatable curtain) module, replacing IC (Inflatable Curtain) Module, Replacing
- Control module SRS (supplemental restraint system), replacing Supplemental Restraint System Module (SRS), Replacing
- Checking wiring and terminals Checking Wiring And Terminals
- Cable harness SRS system, repair Procedures
Continue - Replacing the control module
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
In case of this defect, troubleshooting is not followed by verification.
The information can be displayed again or the fault-tracing for this fault can be interrupted.
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
FAULT FOUND - Fault Found
Attempt New Test - Checking the wiring
-------------------------------------------------
Replacing the control module
Note! Troubleshooting on connectors and wiring must be done before the control module may be replaced.
Since the malfunction may result in internal functions in the Supplemental restraint system module (SRS) not working, the control module must be replaced.
Other information
- Control module SRS (supplemental restraint system), replacing Supplemental Restraint System Module (SRS), Replacing
Continue - Fault-tracing information
-------------------------------------------------