Signal Too Low - Permanent Fault
Signal too low. Permanent fault
Checking components and wiring
Check the resistance of the evaporative emission system (EVAP) valve.
Check the signal cable between control module terminal #A9 (#A9) and evaporative emission system (EVAP) valve terminal 2. Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- To connect the breakout box / access the control module, see Connecting the breakout box, B5244T5, B5254T2 Connecting the Breakout Box
- For the location of components, see Location of components Locations
- For information about signals, see Signal specification Signal Specification, ECM
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reconnect connectors, reinstall components
- Ignition on.
- Activate canister purge (CP) valve.
A "click" should be heard when the canister purge (CP) valve is activated.
Is the canister purge (CP) valve working?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking components and wiring
-------------------------------------------------