FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Signal Too High - Intermittent Fault






Signal too high. Intermittent fault

Checking cables
Check signal cable between heated oxygen sensor (HO2S) #2 and control module #A35 (#A35) for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.

Other information
- Connecting the breakout box/accessing the control module, see Connecting the breakout box, B5244T5, B5254T2 Connecting the Breakout Box.
- To access/replace the heated oxygen sensor (HO2S), see the relevant service procedure.
- For information about signals, see Signal specification Signal Specification, ECM.













Continue - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - Fault Found

------------------------

Attempt New Test - Checking cables

FAULT FOUND - DONE

-------------------------------------------------