Signal Too High. Permanent Fault
Signal too high. Permanent fault
Checking and replacing the component
Replace the relay, 2/91.
Activate the relay for windshield wipers on.
If the function is OK, the cause of the fault was a defective relay (short-circuit in the relay).
Other information:
- For further information about the fuses and relays, see the Wiring Diagram.
Was a fault detected?
Yes - Verification
No - Checking the fusebox
-------------------------------------------------
Checking the fusebox
Remove windshield wiper relay 2/91 from the fusebox base.
Check the relay coil driver circuit for a short-circuit to supply voltage. Take a voltmeter reading between terminal #2 and ground in the relay base.
The voltage between terminal #2 and ground should be approximately 0 volt.
Other information:
- For further information about the fuses and relays, see the Wiring Diagram
- Checking wiring and terminals Checking Wiring And Terminals.
Was the function OK?
Yes - Verification
No - Checking the cable
-------------------------------------------------
Checking the cable
Check the cable between windshield wiper relay base terminal #2 and central electronic module (CEM) terminal #A13. Check for a short-circuit to supply voltage.
Remedy as necessary.
Replace the fusebox if no fault is found.
Other information:
- For further information about the fuses and relays, see the Wiring Diagram
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect connectors, install components etc.
- Ignition on.
Activate the relay, windscreen wiper on.
Does it work?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking and replacing the component
-------------------------------------------------