Signal Too Low
Signal too low
Checking the power supply
Check the supply to Combustion Preheater Module (CPM) #9 for contact resistance and oxidation as described in Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault , or a loose connection as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults. Also check fuse 9 in the engine compartment. The voltage should be 12 V.
Check the cable between #1 on the Ext-X relay (2/29) and #15 on the Combustion Preheater Module (CPM) for contact resistance and oxidation as described in Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault , or for a loose connection as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults. Also check the relay, the supply to the relay and passenger compartment fuse 24.
If no fault has been found, the fault may have been intermittent.
Do the necessary corrective action.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
- Ignition off.
- Connect connector, install components etc.
- Ignition on.
Note! It is important that only the ignition is on for the heater to start up.
- Activate the heater.
A buzzing sound should be heard from the heater.
Check the function of the heater as described in Engine coolant heater, test running Engine Coolant Heater, Test Running.
Additional information:
- For a description of the parameters, see Description of parameters Description of Parameters.
- For a description of activations, see Activating components/functions Activating Components/Functions.
Does the heater work?
Yes - VERIFIED
No - VERIFICATION FAILEDPAPER
------------------------
VERIFICATION FAILED - Trouble-shooting information
VERIFIED - Fault Found
PAPER - No Fault Found
-------------------------------------------------
Trouble-shooting information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the power supply
FAULT FOUND - Fault Found
-------------------------------------------------