Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Intermittent fault
- Ignition off.
Check the cable between fuse 11/C33 terminal #2 and fuel pump (FP) relay 2/23 terminal #3. Check for a short-circuit to ground. Check for an open-circuit. Check for contact resistance and oxidation.
Remedy as necessary.
Other information:
- To access and replace the relay, see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
- For further information about the fuses and relays, see the Wiring Diagram
- For information about signals, see Signal specification Pinout Values and Diagnostic Parameters
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Intermittent fault
FAULT FOUND - DONE
DONE - DONE
-------------------------------------------------