Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Intermittent fault
- Ignition off.
Check the signal cable between central electronic module (CEM) terminal #5A and generator (GEN) terminal #1B (the red / white cable with flat pin) for a short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Intermittent fault
FAULT FOUND - DONE