Faulty Signal
Faulty signal
Replacing the component
The fault has probably occurred as a result of a defective potentiometer or a short-circuit in the potentiometer. If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults can be caused by interference at start up of the control module or may be a different type of fault which occurs on different occasions. The fault is evaluated depending on how it occurs. If the fault recurs, replace the control module.
If the fault persists, replace the climate control module (CCM). The potentiometer cannot be replaced as a separate part.
Other information:
- To access or replace the control module, see Climate control module (CCM), replacing Service and Repair.
Continue - Equipment
-------------------------------------------------
Equipment
Which type of climate control is the car equipped with?
1. Electronic climate control
2. Manual climate control (MCC) / Standard (STD).
Select one of the above options.
1 - Verification 1
2 - Verification 2
-------------------------------------------------
Verification 1
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect the connectors, install the components, etc.
- Ignition on.
- Blower motor on.
Check that damper motor position changes by activating and de-activating from control panel. The values given below are the standard values that the damper motor positions should give.
- Left/right temperature damper motor and defroster, 0-100%
- Recirculation damper motor, 40-100%
- Floor/ventilation damper motor, floor only approximately 39%, ventilation only approximately 87% and floor/ventilation approximately 71%.
Does damper motor work?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Information
VERIFIED - Fault Found
-------------------------------------------------
Verification 2
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect the connectors, install the components, etc.
- Ignition on.
- Blower motor on.
Check that damper motor position changes by activating and de-activating from control panel. The values given below are the standard values that the damper motor positions should give.
Note! Blower motor must be in operation to activate the damper motors.
- Left/right damper motor temperature, 0-100%
- Recirculation damper motor, 40-100%
- Damper motor air distribution, defroster approximately 0%, floor/defroster approximately 19%, floor approximately 39%, ventilation approximately 83%.
Does damper motor work?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Information
VERIFIED - Fault Found
-------------------------------------------------
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
Attempt New Test - Replacing the component
FAULT-TRACING FAILED - No Fault Found
-------------------------------------------------