Checking the TRACS/STC switch circuit
Checking the TRACS/STC switch circuit
Checking activation with TRACS switch
- Ignition on.
- Read off the status of the TRACS/STC switch
- Press in the TRACS switch and hold it in for approximately 2 seconds. Release the switch and wait approximately 5 seconds and then hold it down for approximately a further 2 seconds.
The status of the TRACS/STC switch should fluctuate when pressed in repeatedly. At the same time check that that the TRACS/STC warning lamp lights and goes out.
Is the status changed?
Yes - No Fault Found
No - Checking the wiring and TRACS/STC switch
-------------------------------------------------
Checking the wiring and TRACS/STC switch
- Ignition off
- Remove the TRACS/STC switch and disconnect it.
Check the wiring between TRACS/STC switch #5 and ground for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Check the wiring between TRACS/STC switch #1 and combined instrument panel #29 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Hint: With the ignition off and the TRACS/STC switch disconnected the resistance between #1 and #5 on the switch connector should be 0 ohms when pressed in and infinite when the switch is unaffected.
With the ignition on and the TRACS/STC switch disconnected the voltage between #1 on the switch connector and ground should be approximately battery voltage.
Remedy as necessary.
Other information:
- For connecting the breakout box to the combined instrument panel, see Connecting breakout box, Combined instrument panel Connecting the Breakout Box.
- For information about signals, see Pinout Values and Diagnostic Parameters Connector A, #A1 - #A30.
Was a fault detected?
Yes - Verification
No - No Fault Found
-------------------------------------------------
Verification
- Ignition on.
- Read off the status of the TRACS/STC switch
- Press in the TRACS/STC switch and hold it depressed for approximately 2 seconds. Release the switch and wait approximately 5 seconds and then hold it down for approximately a further 2 seconds.
The status of the TRACS/STC switch should fluctuate when pressed in repeatedly. At the same time check that that the TRACS/STC warning lamp lights and goes out.
Is the status changed?
Yes - FAULT FOUND
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should be diagnosed and remedied. Since this is not the case the fault-tracing process has failed.
Complete the fault-tracing for those fault or try again.
Do you want to terminate fault-tracing at this time?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking activation with TRACS switch
-------------------------------------------------