Signal Specification, ABS/DSTC Control Module
Signal Specification, ABS/DSTC (Dynamic Stability And Traction Control) Control Module
All the values given are between the relevant terminal in column 1 and terminals #A15 or #A46 (ground), unless otherwise indicated in brackets.
NOTE: It is important that the breakout box is connected and that the ground terminals have been checked before readings are taken.
U = DC voltage in volts (V)
Ubat = battery voltage (V)
I = current in amperes (A)
Ulow = voltage approximately 0 V
f = Frequency in Hertz (Hz)