Checking Cables To Turn Signal Lamps
Checking cables to turn signal lamps
Checking programming
Note! Before carrying out this test, check that the car is programmed to emit a visual acknowledgement signal when the alarm is activated.
IND.ACTIVE should display the status ON for the turn signal lamps to flash once when the alarm is armed.
Other information
- For information about programming see Programming parameters/functions Programming Parameters/Functions.
Is the status ON displayed?
Yes - Activating turn signal lamps
Activating turn signal lamps
No - DONE
-------------------------------------------------
Activating turn signal lamps
- Ignition on.
Activate turn signal lamps. The turn signal lamps should light.
Is the function OK?
Yes - No Fault Found
No - Checking connectors
Checking connectors
-------------------------------------------------
Checking connectors
- Disconnect the VGLA control module according to Replacing the control module Replacing the Control Module.
- Check VGLA control module connector for contact resistance and oxidation according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
- Ignition on.
Use the Activation function to activate the turn signal lamps. The turn signal lamps should come on. If the turn signal lamps are activated the cause of the fault has been loose connections in the connector.
Is the function OK?
Yes - Fault has been remedied
No - Checking turn signal lamp function
-------------------------------------------------
Checking turn signal lamp function
- Ignition off.
- Disconnect VGLA control module.
Bridge control module connector terminals A12 and A26.
The left turn signal lamp should light.
Bridge control module connector terminals A13 and A26.
The right turn signal lamp should light.
Is the function OK?
Yes - Replacing component
No - Checking cables
-------------------------------------------------
Checking cables
Check the cable between VGLA control module #12 and the left or right turn signal lamps for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Select Continue when the fault has been remedied.
Continue - Verification
FAULT FOUND
-------------------------------------------------
Replacing component
Replace the control module according to Replacing the control module Replacing the Control Module.
Continue - Verification
Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair check that the fault has been remedied as follows:
- Ignition off.
- Reconnect connectors, reinstall components.
- Ignition on.
Activate turn signal lamps.
The turn signal lamps should come on.
Is the function OK?
Yes - Fault has been remedied
No - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking programming
-------------------------------------------------