Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Intermittent fault
Check the wiring between transmission control module (TCM) #A52 (#A52) and transmission connector A #25 and between control module #A70 (#B10) and between transmission connector #25 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Hint: Check solenoid SLT by measuring the resistance between #24 and #25 on transmission connector B. The ohmmeter should read 5-5.6 ohms (at 20°C).
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box, B5234T9, B5244T7 Connecting The Breakout Box.
- To disconnect transmission connector A, see Replacement Of Control System Cable Harness With Oil Temperature Sensor.
- For information about signals, see Signal description. Transmission control module (TCM), AW55-50/51SN Signal Description AW50-42.
Select Continue when the fault has been remedied.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Intermittent fault
-------------------------------------------------