Internal Fault
Internal fault
Checking shift solenoids
- Ignition on.
- Gear selector in position P.
- Activate shift solenoids S1, S2, S3, S4 and S5 individually.
The status should switch between OFF and ON.
If the status does not switch this indicates an internal fault in the control module.
Does the solenoid status change?
Yes - No Fault Found
No - Replacing the control module
-------------------------------------------------
Replacing the control module
Caution! A new control module is delivered without software. The control module must be programmed in order to function after replacement.
For further information about programming and replacing the control module, see Replacing the gearbox control module (TCM) Replacing the Gearbox Control Module (TCM).
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reconnect the connectors, reinstall components etc.
- Ignition on.
- Gear selector in position P.
- Activate shift solenoids S1, S2, S3, S4 and S5 individually.
The status should switch between OFF and ON.
Does the status change?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - FAULT FOUND
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking shift solenoids
-------------------------------------------------