Checking Power Supply and Ground For MCC Control Module
Checking Power Supply And Ground For MCC Control Module
Check that fuses 31 and 7 are intact. If any fuses are blown, check the circuit after the fuse for a short-circuit to ground according to Checking wiring and terminals - Permanent faults
Hint: For further information about the circuit after the fuse, see the Wiring Diagram.
Then replace the fuse.
Check MCC control module connector for contact resistance and oxidation according to Checking wiring and terminals - Permanent faults Checking Wiring and Terminals
Check power supply to MCC control module #B6 and #B 17 for an open circuit according to Checking wiring and terminals - Permanent faults Checking Wiring and Terminals
Check ground lead between MCC control module #B 16 and ground terminal for an open-circuit according to Checking wiring and terminals - Permanent faults Checking Wiring and Terminals
Remedy as necessary
Other information:
- To connect the breakout box Connection of Breakout Box MCC
After performing this procedure, Verification