Check the Central Locking System Cable For Short-Circuit
Check The Central Locking System Cable For A Short-circuit To Ground
- Ignition off
- Disconnect the battery negative lead.
- Connect the SRS control module connector.
- The connector for the central locking system control module must be disconnected.
Connect an ohmmeter between ground and central locking system connector #10 A
The ohmmeter should read approximately 1.2 M[ohm].
OK - Replacing the Component - I
Not OK - Checking Cable Between Central Locking System Ctrl and SRS Ctrl