FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Short-Circuit to Ground, Permanent Faults



Short-circuit to ground





A short-circuit between a live cable and ground is often indicated by the loss of a function or a fuse blowing when a current is passed through the cable.
To repair wiring and cable terminals

Checks:
- Check the cables visually. Checking Wiring and Terminals. Permanent Fault
- Activate all switches and sensors in the circuit. Check whether the fuse blows
- Disconnect the connectors in the circuit to ensure that they do not affect readings.

Use an ohmmeter to take a resistance reading between the cable and ground.
The ohmmeter should read infinite resistance if no components are connected.
If the value is not correct, try a new cable and/or continue according to "Contact Resistance and Oxidation". Contact Resistance and Oxidation