2. Checking Resistance In Lock-Up Solenoid SL Circuit
Checking Resistance In Lock-Up Solenoid SL Circuit
- Ignition off
- Disconnect the control module. See Replacing the transmission control module (TCM)
- Connect the breakout box. See Connecting breakout box, Transmission control module (TCM).
Connect an ohmmeter between breakout box:
#51 (#A51) and #53 (#A53), lock-up solenoid SL.
The ohmmeter should read 12-18 Ohms.
OK: Refer to Test Driving. 3. Test Driving
NOT OK: Refer to Checking For Contact Resistance and Oxidation. 6. Checking For Contact Resistance and Oxidation