Checking Cables and Sensors
Checking Cables And Sensors
Check transmission speed sensor cable for power supply between control module #A59 and transmission connector #16 and between the transmission connector and the speed sensor connector for an open-circuit according to Checking wiring and terminals. Permanent faults, a short-circuit to ground according to Checking wiring and terminals. Permanent faults and a short-circuit to supply voltage according to Checking wiring and terminals. Permanent faults.
HINT: With control module connected and ignition on, the voltage between connector #1 and ground (breakout box #53) should be approximately 8-12 V.
Check speed sensor power supply between control module #A41 and automatic transmission connector #17 and between automatic transmission connector #17 and speed sensor connector for an open-circuit according to Checking wiring and terminals. Permanent faults , a short-circuit to ground according to Checking wiring and terminals. Permanent faults and a short-circuit to supply voltage according to Checking wiring and terminals. Permanent faults.
Remedy as necessary.
Other Information:
- To connect the breakout box, see Connecting breakout box, Transmission control module (TCM).
- To disconnect transmission connector, see Inspecting/cable harness to solenoids.
- To replace the speed sensor, see Replacing transmission speed sensor.
- For information about signals, see Signal specification, Transmission control module (TCM).
Was a fault detected?
YES: Refer to Verification. Verification
NO: Refer to Trouble Code Descriptions. Diagnostic Trouble Code Descriptions