Checking Wiring and Sensors
Checking Wiring And Sensors
- Ignition off.
Check the transmission control module (TCM) and speed sensor connectors for contact resistance and oxidation according to.
Check the power supply cable between transmission control module (TCM) terminal A59 and transmission connector terminal 16 for an open-circuit according to Checking wiring and terminals. Permanent faults.
Check the signal cable between transmission control module (TCM) terminal A41 and transmission connector terminal 17 for an open-circuit according to Checking wiring and terminals. Permanent faults.
HINT: With the transmission control module connected, the ignition on and a voltmeter connected between transmission connector terminals 16 and 17 (control module side), the voltage should be approximately 1 V below Ubat.
Remedy as necessary.
Other Information:
- To connect the breakout box, see Connecting breakout box, Transmission control module (TCM).
- To disconnect the transmission control module (TCM), see Replacing the transmission control module (TCM).
- To disconnect transmission connector, see Inspecting/cable harness to solenoids.
- For information about signals, see Signal specification, Transmission control module (TCM).
Continue: Refer to Verification. Verification