Checking Wiring and Components
Checking Wiring And Components
- Ignition off.
Check cable between control module #A51 and transmission connector (control module side) #23 for a short-circuit to ground according to Checking wiring and terminals. Permanent faults.
Check cable between transmission connector (transmission side) #23 and lock-up solenoid SL for a short-circuit to ground according to Checking wiring and terminals. Permanent faults.
HINT: With the ignition off and control module disconnected the resistance between control module #A51 and ground (breakout box #53) should be 11-15 Ohms.
Remedy as necessary.
Other Information:
- To connect the breakout box, see Connecting breakout box, Transmission control module (TCM).
- To disconnect transmission connector, see Inspecting/cable harness to solenoids.
- To check/replace lock-up solenoid SL, see Inspecting/replacing solenoids.
- For information about signals, see Signal specification, Transmission control module (TCM).
Select Continue when the fault has been remedied.
Continue: Refer to Resetting the Adaptation. Resetting the Adaptation