2. Intermittent Fault
Intermittent Fault
Check cable between control module #A68 (#B8) and solenoid S2 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults and contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults.
HINT: Voltage should be approximately 12 V with the ignition on and voltmeter connected to control module #A68 (#B8) and ground.
Remedy as necessary.
Other Information:
- To connect the breakout box, see Connecting breakout box, Transmission control module (TCM).
- For other values, see Signal specification, Transmission control module (TCM).
Select Continue when the fault has been remedied.
Continue: Refer to Fault-Tracing Information - Intermittent Fault. Fault-Tracing Information - Intermittent Fault