3. Checking Wiring and Components
Checking Wiring And Components
- Ignition off.
Check cable between control module #A50 and transmission connector (control module side) #21 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent faults.
Check cable between transmission connector (transmission side) #21 and solenoid S1 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent faults.
Remedy as necessary.
Other Information:
- To connect the breakout box, see Connecting breakout box, Transmission control module (TCM).
- To disconnect transmission connector, see Inspecting/cable harness to solenoids.
- To check/replace shift solenoid S1, see Inspecting/replacing solenoids.
- For information about signals, see Signal specification, Transmission control module (TCM).
Select Continue when the fault has been remedied.
Continue: Refer to Resetting the Adaptation. 4. Resetting the Adaptation