Checking the Wiring
Checking The Wiring
- Check that the bulb is intact.
- Ignition off.
- Disconnect the Control unit.
Connect an ohmmeter between Control unit #25 and ground and check for a short circuit to ground, as described in Checking wiring and terminals - Permanent faults.
If there is a short circuit to ground, replace the wire or repair it, otherwise the fault lies in the combined instrument.
Checking Wiring and Terminals - Permanent Faults
Do the necessary corrective action.
After performing this procedure Verification