FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Signal Too Low - Intermittent Fault




Intermittent Fault







- Ignition off.

Check the wiring between control module #A6 and passenger door central locking switch #C3 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.

Check the wiring between control module #A4 and passenger door central locking switch #C5 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.

Check the wiring between control module #A16 and passenger door central locking switch #C6 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.

Checking Wiring and Terminals - Intermittent Faults

Remedy as necessary.

Other information:
- For further information about signals and other values, see Control Module Pinout Values.
- To connect the breakout box, Reading and Clearing Diagnostic Trouble Codes