Signal Too Low - Intermittent Fault
Intermittent Fault
- Ignition off.
Check the wiring between control module #A6 and passenger door central locking switch #C3 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.
Check the wiring between control module #A4 and passenger door central locking switch #C5 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.
Check the wiring between control module #A16 and passenger door central locking switch #C6 for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.
Checking Wiring and Terminals - Intermittent Faults
Remedy as necessary.
Other information:
- For further information about signals and other values, see Control Module Pinout Values.
- To connect the breakout box, Reading and Clearing Diagnostic Trouble Codes