Checking Cable
Checking Cable
- Ignition off.
Disconnect VGLA control module connector A.
Connect an ohmmeter between contact reel #A10 and ground, measure for a short-circuit to ground according to Checking wiring and terminals - Permanent faults.
Checking Wiring and Terminals - Permanent Faults
Remedy as necessary.
Other information:
- For further information about signals and other values, see Control Module Pinout Values.
- To connect the breakout box, Reading and Clearing Diagnostic Trouble Codes
Was a fault found?
Yes - Verification