Signal Too Low - Intermittent Fault, Checking Cable
Checking Cable
- Ignition off.
Disconnect VGLA Control module connector A.
Connect an ohmmeter between #A 10 and ground, measure for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.
Checking Wiring and Terminals - Intermittent Faults
Remedy as necessary.
Other information:
- For further information about signals and other values, see Control Module Pinout Values.
- To connect the breakout box, Reading and Clearing Diagnostic Trouble Codes