Checking Cables
Checking Cables
- Ignition off.
Check fuse 6.
Hint: If the fuse is blown, check the circuit after fuse 6 for an open-circuit according to Checking wiring and terminals - Permanent faults.
Check the cable between control module #B15 and siren #5 for a short-circuit to ground according to Checking wiring and terminals - Permanent faults and for an open-circuit according to Checking wiring and terminals - Permanent faults. Check the cable between fuse 6 and siren #4 for an open-circuit according to Checking wiring and terminals - Permanent faults.
Checking Wiring and Terminals - Permanent Faults
Other information:
- The voltage between siren #4 and ground should be battery voltage.
- For further information about signals and other values, see Control Module Pinout Values.
- To connect the breakout box, Reading and Clearing Diagnostic Trouble Codes
Remedy as necessary.
After performing this procedure Erasing Diagnostic Trouble Codes (DTCs)