Checking Cables
Checking Cables
- Expose VGLA Control module.
- Disconnect siren.
- Disconnect siren connector.
- Ignition on.
Check fuse 29.
Check the cable between #4 on the 15-I rail in the relay box and siren connector #1 for an open-circuit according to Checking wiring and terminals - Permanent faults and a short-circuit to ground according to Checking wiring and terminals - Permanent faults. Check siren and control module connectors for contact resistance and oxidation according to Checking wiring and terminals - Permanent faults.
Checking Wiring and Terminals - Permanent Faults
Other information:
- The voltage between siren connector #1 and ground should be battery voltage when the ignition is on.
Remedy as necessary.
Was a fault detected?
Yes - Erasing Diagnostics Trouble Codes (DTCs) - II
No - Replacing Component