Faulty Signal - Permanent Fault
ECM-8010 SYSTEM RELAY OUTPUT
FAULTY SIGNAL - PERMANENT FAULT
Checking wiring
Check the cable between system relay terminal 3 and control module terminal A70 (#B10) for an open-circuit according to [1][2]Checking Wiring and Terminals. Permanent Fault and a short-circuit to ground according to [1][2]Checking Wiring and Terminals. Permanent Fault
Try a new system relay if no fault is found during the above fault-tracing.
Remdy as necessary.
Verification
Hint: After carrying out the repait, check that the fault has been remedied.
- Ignition off
- Reinstall connectors, components, ect.
- Start the engine
Does the engine start?
Yes - Testing Complete.
No - Continue below.
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed. Exit fault tracing for this diagnostic trouble code (DTC) or make another attempt.