Signal Too High - Intermittent Fault
ECM-6440 CAMSHAFT RESET VALVE
SIGNAL TOO HIGH - INTERMITTENT FAULT
Checking wiring and connectors
Check the signal cable between engine control module (ECM) # A13 and camshaft reset valve # 2 for an intermittent short-circuit to supply voltage according to [1][2]Checking Wiring and Terminals. Intermittent Faults
Other information:
- To connect the breakout box Connecting the Breakout Box (ECM)
- To access/replace the camshaft reset valve, Variable Valve Timing Solenoid, Replacing
- With the ignition on and camshaft reset valve connector disconnected the voltage on connector # 1 should be approximately Ubat and connector # 2 be a pulse modulated signal with top voltage at approximately Ubat and with a frequency of approximately 250 Hz.
- For information about signals, see Diagnostic Parameters and Pinout Values. Signal Description, ME7, B5XX4T
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.