Signal Missing - Permanent Fault
ECM-6120 ENGINE COOLING FAN RELAY, FAULTY SIGNAL
SIGNAL MISSING - PERMANENT FAULT
Checking component and wiring
Check engine cooling fan (FC) relay connector for contact resistance and oxidation according to [1][2]Checking Wiring and Terminals. Permanent Fault
Check power supply cable for an intermittent open-circuit according to [1][2]Checking Wiring and Terminals. Permanent Fault, also check that the fuse has not blown.
Check cable between engine control module (ECM) # A6 and engine cooling fan (FC) relay # IN2 for an intermittent open-circuit according to [1][2]Checking Wiring and Terminals. Permanent Fault
Remedy as necessary
Other information
- Connecting the breakout box/accessing the control module Connecting the Breakout Box (ECM)
- For information about signals, see Diagnostic Parameters and Pinout Values. Signal Description, ME7, B5XX4T
- The engine cooling fan (FC) relay is supplied with power via fuse 11A/1.
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reinstall connectors, components etc.
- Disconnect the Volvo Scan Tool (ST) from the VIDA station. Use it in stand alone mode and connect it to the data link connector (DLC) in the car.
- Ignition on.
- Go into scrolling values.
Check the outside temperature reading is correct. Compare with the actual air temperature.
Is the temperature reading OK?
Yes - Testing Complete.
No - Continue below.
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed. Exit fault tracing for this diagnostic trouble code (DTC) or make another attempt.