Diagnostic Trouble Code (DTC) Information
ECM-1000 CONTROL MODULE
DIAGNOSTIC TROUBLE CODE (DTC) INFORMATION
Condition
If the control module registers that a signal from the internal atmospheric pressure sensor is faulty, the control module interprets this as a fault and ECM-1000 is stored after 20 seconds.
Condition
The control module assumes 1013 hPa (14.7 psi) air pressure corresponding to sea level.
Possible source
Signal too high:
- defective control module
Signal too low:
- defective control module
Condition
- Malfunction indicator lamp (MIL) lit