FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Checking Cables




Checking Cables






Check the Control module and the damper motor connectors for contact resistance and oxidation according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals

Check signal cable between MCC control module #B13 and damper motor terminal 3 for an open-circuit according to Checking wiring and terminals - Permanent faults, and a short-circuit to supply voltage according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals

Check ground lead between MCC control module #B11 and damper terminal 1 for an open-circuit according to Checking wiring and terminals, Permanent faults. Checking Wiring and Terminals

Check cable for power supply between MCC control module #B12 and damper motor terminal 2 for a short- circuit to supply voltage according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals

If cables are OK, try a new air distribution damper motor.

Remedy as necessary.

Other information:

- To connect the breakout box Connection of Breakout Box ECC
- Voltage on signal cable varies between approximately 0-5 V depending on damper motor position. Damper motor power supply should be approximately 5 V. For other values Signal Specification MCC

After performing this procedure Self-Adjusting of Shutter Motor End Position