Checking Cables
Checking Cables
Check the control module and power unit connectors for contact resistance and oxidation according to Checking wiring and terminals - Permanent faults.
Check cable between control module #A14 and power unit for a short-circuit to ground according to Checking wiring and terminals - Permanent faults.
Check power supply to power unit #A4 for an open-circuit according to Checking wiring and terminals - Permanent faults.
Check ground lead between power unit #B2 and ground terminal for an open-circuit according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals
Remedy as necessary.
Other information:
- To remove the control module, refer to Replacing ECC Control Module.
- To access the power unit, refer to Replacing power unit (ECC).
After performing this procedure Verification