Checking Components and Cables
Checking Components And Cables
Check cable between ECC control module #AB8 and passenger compartment temperature sensor terminal 4 for an open-circuit according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals
Check the cable between passenger compartment temperature sensor terminal 2 ground terminal for an open- circuit according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals
Check that the fan motor is OK, the fan turns easily and the motor is not short-circuited internally.
Hint: A short-circuit on the ground lead can be caused by a short-circuit to supply voltage. Always check the signal cable for this fault cause as well.
Remedy as necessary.
Other information:
- Breakout box connection Connection of Breakout Box ECC
- Voltage on the control signal lead should be battery voltage approximately when the fan is activated. For other values refer to Signal Specifications ECC Signal Specification ECC
After performing this procedure Verification