FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Reading Off the Control Module ID






Reading off control module ID

Reading off control module ID




- Ignition on or start engine.
Activate reading off control module ID by clicking the symbol for VCT 2000.






Continue - DONE

Numeric Result 0 - Communication fault

-------------------------------------------------

Communication fault




Communication fault

Communication fault
Communication has been interrupted for one of the following reasons:
- The ignition is switched off
- VCT2000 disconnected from the data link connector (DLC)
- VCT2000 disconnected from the VIDA cart
- Communication problems in VIDA application or in car.
- No voltage in the data link connector (DLC).

Check therefore:
- That the control module power supply and ground terminal are fault-free.
- That the fuse for the data link connector (DLC) is intact.
- that the ignition is on
- that the battery voltage (system voltage) is normal (approximately 12 V).
If necessary a battery charger can be connected during the test.
For information about charge currents and the battery, see: Battery, charging Battery, Charging
- that VCT2000 is correctly connected to the VIDA cart and the data link connector (DLC)
- that VCT2000 and the wiring is fault-free.

Other information
- For information about fuse and terminal numbers, see the relevant Wiring Diagram.
Try to establish communication again or exit reading off diagnostic trouble codes (DTCs). Depending on the communication fault, select one of the following options.
1. Try again
2. Fault-trace more comprehensively for the communication problem that has occurred
3. Exit fault-tracing / Read off from the next system.





Which alternative is requested?

1 - 1

2 - 2

3 - 3

------------------------

1 - Reading off control module ID

2 - Checking communication

3 - Exit fault-tracing / Read off from the next system

-------------------------------------------------

Checking communication
Corrective action to ensure communication fault-tracing.

Continue - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Fault-tracing information

Fault-tracing information
Fault-tracing communication problems is now finished.

Do you want to try establishing communication again?

Yes - YES

No - NO

------------------------

YES - Reading off control module ID

NO - FAILED

-------------------------------------------------