Checking Cables
Checking Cables
- Ignition off.
- Remove the door panel from the relevant door.
Check the circuit for the relevant door as follows:
For the left front and rear doors: check the cable between VGLA control module #A2 and the relevant gray lock unit connector terminal 4 for an open-circuit according to Checking wiring and terminals - Permanent faults. For the right front and rear doors: check the cable between VGLA control module #A15 and the relevant gray lock unit connector terminal 1 for an open-circuit according to Checking wiring and terminals - Permanent faults. Also check the gray lock unit connector for the relevant door for oxidation and contact resistance, according to Checking wiring and terminals - Permanent faults.
Remedy as necessary.
Checking Wiring and Terminals - Permanent Faults
After performing this procedure Verification