Verification
Verification
Hint: After carrying out the repair check that the fault has been remedied.
- Ignition off
- Reconnect the connectors, reinstall components etc.
- Connect the breakout box
- Connect an ohmmeter between terminals #A16(A16) and #A1(A1).
Turn the key in the driver's door to the locking position. The value must be infinite when the lock is unaffected and 0 [ohm] when the key is turned to the locking position.
- Connect an ohmmeter between terminals #A18(A18) and #A1(A1).
Turn the key in the driver's door to the unlocking position.
The value must be infinite when the lock is unaffected and 0 [ohm] when the key is turned to the unlocking position.
Other information
- To connect the breakout box, Reading and Clearing Diagnostic Trouble Codes