Checking Communication Cable to Data Link Connector (DLC)
Checking Communication Cable To Data Link Connector (DLC)
- Ignition off.
- VGLA control module disconnected.
- Disconnect VCT 2000 from the data link connector (DLC).
Connect an ohmmeter between data link connector (DLC) terminal 7 and VGLA control module connector #B19.
The ohmmeter should read approximately 0 [ohm].
OK - Checking For an Open-Circuit
Not OK - Checking the Communication Cable