Checking Cables
Checking Cables
- Ignition off.
- Disconnect VGLA control module. Check fuse 6.
Hint: If fuse 6 has blown, fault-trace the circuit after fuse 6 for a short-circuit to ground according to Checking wiring and terminals - Permanent faults, for further information about the circuit after the fuse, see the Wiring Diagrams.
Check circuit before fuse 6 for an open-circuit according to Checking wiring and terminals - Permanent faults. Check cable between fuse 6 and VGLA control module #B1 for an open-circuit according to Checking wiring and terminals - Permanent faults. Check cable between VGLA control module #A1 and ground for an open-circuit, according to Checking wiring and terminals - Permanent faults.
Checking Wiring and Terminals - Permanent Faults
Other information:
- The voltage between VGLA control module #B1 and ground should be battery voltage.
Remedy as necessary.
After performing this procedure Verification