Checking Power Supply To RTI Control Module
Checking power supply to RTI control module
Check function
- Ignition off.
Try to activate the RTI system with the remote control.
Can the RTI system be activated?
Yes - Checking cables
No - No Fault Found
-------------------------------------------------
Checking cables
Check the cable between overload relay 2/30 terminal 3 and the RTI control module #B2 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Note! Check the other cables in the relay circuit for a short-circuit to supply voltage Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Check control cable between overload relay 2/30 terminal 3 and ignition switch for a short-circuit to supply voltage for a short-circuit to supply voltage Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
If no faults are detected in the cables, try a new relay.
Remedy as necessary.
Other information:
-------------------------------------------------