Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Checking the connector and cable
- Make a note of the anti-theft radio code.
- Ignition off.
- Disconnect the battery negative lead.
- Disconnect the control module.
Connect an ohmmeter between control module #25 and control module battery voltage #5. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- To access / replace the control module, see SRS control module Service and Repair.
Select Continue when the fault has been remedied.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT-TRACING FAILED - DONE
Attempt New Test - Checking the connector and cable
-------------------------------------------------