Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Checking component
- Ignition off.
- Disconnect the solenoid connectors.
- Disconnect the control module.
For S1: Connect an ohmmeter between the control module 4 and ground and between 5 and ground. Test for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
For S2: Connect an ohmmeter between the control module 17 and ground and between 21 and ground. Test for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- To disconnect / replace the control module, see Replacing the Roll-over Protection System (ROPS) module Service and Repair.
- To disconnect / replace the solenoid connector, see Replacing the roll-over bar cassette Removal and Replacement.
Select Continue when the fault has been remedied.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT-TRACING FAILED - DONE
Attempt New Test - Checking component
-------------------------------------------------