Signal Too High. Permanent Fault
Signal too high. Permanent fault
Checking the connectors and cables
- Make a note of anti-theft radio code.
- Ignition off.
- Disconnect control module.
For S1: Take readings between control module 6 and 5 and between 2 and 5 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
For S2: Take readings between control module 6 and 21 and between 2 and 21 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
The cable harness must be replaced where no repairs may be made to the cable harness.
Remedy as necessary.
Other information:
- To disconnect/replace control module, see Replacing the Roll-over Protection System (ROPS) module Service and Repair.
Select Continue when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied as follows.
- Ignition off.
- Wait 10 seconds so that the system is unpowered.
- Reinstall connectors, components etc.
- Ignition on.
- Read off diagnostic trouble codes (DTCs).
If the DTC status changed to intermittent it means that the fault is no longer present.
Does the status change?
Yes - Verification, continued
No - VERIFICATION FAILED
------------------------
Verification, continued
- Ignition off.
- Press down the roll-over bars if they are deployed.
- Ignition on.
Activate the solenoids.
Warning! Nobody is permitted to be in the vicinity of the roll-over bars when they are being activated.
Did the solenoids activate ?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - FAULT FOUND
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the connectors and cables
-------------------------------------------------