Signal Too Low
Signal too low
Checking outside temperature sensor function
- Ignition on.
- Read off outside temperature.
Check the outside temperature reading is correct. Compare with the actual air temperature.
Is the temperature reading OK?
Yes - Intermittent fault
No - Checking component and cables
-------------------------------------------------
Checking component and cables
Check outside temperature sensor resistance. For resistance values, see Component resistance values Component Resistance Values.
Check cable between control module #7 and outside temperature sensor terminal 1 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Remedy as necessary.
Other information:
- To access the control module/connect breakout box see.
- To access/replace the outside temperature sensor see Replacing outside temperature sensor and glow plugs Service and Repair.
- With ignition on and outside temperature sensor connector disconnected, the voltage between outside temperature sensor connector terminal 1 (control module side) and ground should be approximately 5 V.
- For other values, see Signal specification Additional heater 912-D/B Signal Specification Additional Heater 912-D/B.
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reinstall connectors, components etc.
- Ignition on.
- Read off outside temperature.
Check the outside temperature reading is correct. Compare with the actual air temperature.
Is the temperature reading OK?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - FAULT FOUND
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking outside temperature sensor function
-------------------------------------------------
Intermittent fault
Check cable between control module #7 and outside temperature sensor terminal 1 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- To access the control module/connect breakout box see.
- To access/replace the outside temperature sensor see Replacing outside temperature sensor and glow plugs Service and Repair.
- With ignition on and outside temperature sensor connector disconnected, the voltage between outside temperature sensor connector terminal 1 (control module side) and ground should be approximately 5 V.
- For other values, see Signal specification Additional heater 912-D/B Signal Specification Additional Heater 912-D/B.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking outside temperature sensor function
FAULT-TRACING FAILED - DONE
-------------------------------------------------