Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Checking cable
- Ignition off.
Disconnect VGLA control module connector A.
Connect an ohmmeter between #A10 and ground, measure for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm (VGLA) Signal Specification, Lock and Alarm (VGLA).
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting the Breakout Box.
- To access the control module connector, see Replacing the control module Replacing the Control Module.
Continue - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking cable
-------------------------------------------------