Signal Too High
Signal too high
Checking signal from airing module
- Ignition on.
Read off airing module status.
The value should be OFF.
Is the value OFF?
Yes - Intermittent
No - Checking cables
-------------------------------------------------
Checking cables
Check the cable between the control module #A21 and the airing module terminal 5 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm (VGLA) Signal Specification, Lock and Alarm (VGLA).
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting the Breakout Box.
Select Continue when the fault has been remedied.
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied as follows:
- Ignition on.
- Reinstall connectors, components etc.
Read off airing module status.
The value should be OFF.
Is the value OFF?
Yes - FAULT FOUND
No - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking signal from airing module
-------------------------------------------------
Intermittent
Check the cable between control module #A21 and airing module terminal 5 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Other information:
- For further information about signals and other values, see Signal specification, lock and alarm (VGLA) Signal Specification, Lock and Alarm (VGLA).
- To connect the breakout box, see Connecting the breakout box, lock and alarm (VGLA) Connecting the Breakout Box.
Continue - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking signal from airing module
-------------------------------------------------