Checking Cable
Checking Cable
- Ignition off.
Disconnect the control module connectors.
Disconnect the cable harness for connector 24/9 A.
Check connector for contact resistance and oxidation according to Checking wiring and terminals - Permanent faults
Check #5A and #6A on both the male and female terminals for a short-circuit to ground Checking wiring and terminals - Permanent faults and a short-circuit to supply voltage according to Checking wiring and terminals - Permanent faults.
If short-circuit is found when measured at the female terminal the fault is in the connector or cable to the ultrasonic sensors.
If short-circuit is found when measured at the male terminal the fault is in the connector or cable to the siren or control module.
Remedy as necessary.
Was a fault found?
Yes - Verification
No - Replacing Component